Cooling Towers by Dolphin Group
Equipment

Cooling Towers

Induced-draft cooling towers engineered for Gulf wet-bulb conditions, with fabrication, installation, and fill replacement support from Abu Dhabi.

Scroll Down

The Anatomy of a
Cooling Tower

Fan & Stack

The induced-draft fan on the deck that pulls warm saturated air up through the tower and out through the stack.

Drag to rotate

For representation purposes only.

Built to
Solve

Engineered against the specific failures that cost operators downtime, contamination or wasted energy.

Asset protection

A tower that misses its design cold-water temperature pushes every downstream exchanger and condenser off duty. Fill selection and water-quality mismatches show up as scale, biofilm and structural rot years before a rebuild is budgeted for.

Process integrity

Cooling water temperature sets the ceiling on every process and utility exchanger fed from the loop. A tower undersized for the region's peak wet-bulb temperature caps plant capacity on the hottest days of the year — exactly when demand is highest.

Operational efficiency

Poor air/water distribution wastes fan power for the same cooling duty. In-region fill and drift eliminator stock turns a fouled cell around in days instead of the months an imported rebuild takes.

Why Dolphin Group for
Cooling Towers

ADNOC-approved, Local+ Certified

Qualified to the procurement standards ADNOC group companies require, with in-country value that scores directly on operator and EPC tenders.

Regional thermal design expertise

Four decades of sizing cooling water systems against the Gulf's wet-bulb extremes, not imported design assumptions that undersize the tower.

Rapid cell turnaround

Standing fill, eliminator and mechanical spares stock in Mussafah keeps a fouled or damaged cell down for days, not the months an overseas rebuild takes.

Key
Benefits

What sets cooling towers from Dolphin Group apart, in specific and measurable terms.

  • 1

    Sized for Gulf wet-bulb extremes

    Thermal design against regional peak wet-bulb data, not a generic climate assumption, so the tower holds duty on the hottest day of the year.

  • 2

    Standing fill and eliminator stock

    Local stock of film fill and drift eliminators cuts a fouled-cell turnaround from months to days.

  • 3

    FRP and galvanised options

    Casing and structure matched to the makeup water chemistry and site environment for maximum service life.

  • 4

    In-house rebuild capability

    Full cell rebuilds — fill, distribution, eliminators, fan — executed without importing a complete new tower.

  • 5

    Reduced drift losses

    High-efficiency eliminators cut water and chemical loss to atmosphere, reducing make-up cost and environmental impact.

  • 6

    Documented thermal performance

    Guaranteed approach and range backed by thermal design calculations, not a nameplate estimate.

Technical
Specifications

Design codes, materials and testing scope confirmed for every cooling towers order.

Configuration

Induced-draft counterflow / forced-draft crossflow

Fill type

Film fill (PVC) · splash fill for high-fouling water

Casing/structure

FRP pultruded · hot-dip galvanised steel

Drift loss

As low as 0.001% of circulating flow

Design basis

Site-specific wet-bulb, approach and range

Fan drive

Direct or gear/belt drive, variable-speed option

Design and Manufacturing

Thermal design against site-specific wet-bulb data through fabrication and installation, using FRP or galvanised steel matched to the makeup water chemistry.

Refurbishment

Full cell rebuilds — fill, distribution, eliminators and fan — engineered into an existing structure at a fraction of full replacement cost.

Servicing

Fill and eliminator inspection, cleaning and thermal performance verification that confirm the tower still holds its design approach and range.

Long Term Contracts

Scheduled fill and eliminator turnaround programmes, backed by standing local stock, that keep a fouled cell down for days rather than months.

Where It's
Used

Cooling Towers in service, sector by sector, application by application.

Power & Energy: Cooling Towers applications

Power & Energy

Heat exchangers for power plants in the UAE: HEI-standard condensers, coolers and heat recovery equipment for conventional and renewable generation.

View Sector
Petrochemicals: Cooling Towers applications

Petrochemicals

Heat exchangers for petrochemical plants in the UAE: we build exchangers and reboilers for crackers, polymer plants and aromatics complexes worldwide.

View Sector
Oil & Gas: Cooling Towers applications

Oil & Gas

Heat exchangers for oil and gas in the UAE: thermal equipment engineered for upstream, midstream and refining service, built and serviced in Abu Dhabi.

View Sector
Steel & Metallurgy: Cooling Towers applications

Steel & Metallurgy

Steel plant heat exchangers and cooling equipment: furnace cooling, quench systems and dust-laden gas coolers built for the hardest environments in industry.

View Sector
Chemical Manufacturing: Cooling Towers applications

Chemical Manufacturing

Heat exchangers for chemical plants in the UAE: corrosion-resistant exchangers and vessels for acids, alkalis and speciality chemistry.

View Sector
Data Centers: Cooling Towers applications

Data Centers

Data center cooling systems in the UAE: high-availability cooling infrastructure for the world’s fastest-growing digital economy.

View Sector

Frequently Asked Questions

From single-cell package towers to multi-cell field-erected structures sized for major power and process cooling water duties.

Yes. Fill, distribution, drift eliminators and mechanical components are re-engineered into the existing structure where the casing and structure remain sound.

Thermal design uses site-specific design wet-bulb temperature data — a generic or imported climate assumption will undersize the tower for Gulf summer extremes.

Splash fill or wider-flute film fill resists fouling better than fine-channel film fill where makeup water carries higher suspended solids.

Both — FRP pultruded structures for maximum corrosion life, or hot-dip galvanised steel where capital cost is the priority.

Yes. High-efficiency drift eliminators and low-noise fan options are available where site proximity requires it.

Yes. Dolphin Group is ADNOC-approved and Local+ Certified — one of roughly 70 Local+ Certified companies in the UAE.

Send your heat load, flow rate and site wet-bulb design temperature through our RFQ form or to connect@dolphin.ae — we typically respond within two working days.

Talk to an Engineer About Cooling Towers

Send your duty requirements or existing datasheet, and our engineers will confirm the right configuration.

Talk to an Engineer